@@ -297,20 +297,18 @@ func (ctl *Control) GetWorkConn() (workConn net.Conn, err error) {
|
||||
}
|
||||
|
||||
func (ctl *Control) heartbeatWorker() {
|
||||
xl := ctl.xl
|
||||
|
||||
// Don't need application heartbeat if TCPMux is enabled,
|
||||
// yamux will do same thing.
|
||||
// TODO(fatedier): let default HeartbeatTimeout to -1 if TCPMux is enabled. Users can still set it to positive value to enable it.
|
||||
if !lo.FromPtr(ctl.serverCfg.Transport.TCPMux) && ctl.serverCfg.Transport.HeartbeatTimeout > 0 {
|
||||
go wait.Until(func() {
|
||||
if time.Since(ctl.lastPing.Load().(time.Time)) > time.Duration(ctl.serverCfg.Transport.HeartbeatTimeout)*time.Second {
|
||||
xl.Warnf("heartbeat timeout")
|
||||
ctl.conn.Close()
|
||||
return
|
||||
}
|
||||
}, time.Second, ctl.doneCh)
|
||||
if ctl.serverCfg.Transport.HeartbeatTimeout <= 0 {
|
||||
return
|
||||
}
|
||||
|
||||
xl := ctl.xl
|
||||
go wait.Until(func() {
|
||||
if time.Since(ctl.lastPing.Load().(time.Time)) > time.Duration(ctl.serverCfg.Transport.HeartbeatTimeout)*time.Second {
|
||||
xl.Warnf("heartbeat timeout")
|
||||
ctl.conn.Close()
|
||||
return
|
||||
}
|
||||
}, time.Second, ctl.doneCh)
|
||||
}
|
||||
|
||||
// block until Control closed
|
||||
|